Find the hidden disturbances that trip drives, overheat transformers and inflate your bills, using certified class-A power quality analysers.

Class-A AnalysersIEEE 519IEC 61000-4-30
Overview

Anomaly detection in harmonics, transients, dips and swells, before they damage equipment.

Poor power quality costs industry through nuisance tripping, overheated cables and transformers, failed electronics and penalties for low power factor. Our engineers install portable class-A analysers at critical points of your network and record every event over a representative period.

We then turn raw data into an actionable report: the root cause of each disturbance, its impact, and engineered fixes such as harmonic filters, PFI correction, or protection and wiring changes.

Power Quality Analysis
7daysTypical logging period
50thHarmonic order captured
100%Data-backed findings

What's included

Harmonic analysis

THD and individual harmonic measurement, checked against IEEE 519 limits.

Transients & surges

Capture of high-speed transients from switching, lightning and VFDs.

Dips & swells

Voltage sag and swell events, correlated with process trips and downtime.

Power factor & load

Load profiling, demand peaks, unbalance and power factor trend analysis.

Root-cause diagnosis

Correlation of events with equipment behaviour to pinpoint the true source.

Mitigation design

Specification of active/passive filters, PFI panels and protection upgrades.

Backed by S.A. Hamid & Co. since 1964

Engineering depth, in-house manufacturing and disciplined site execution from one accountable team.

Our approach

  1. Scoping

    Understand the symptoms, the single-line diagram and the critical loads.

  2. Measurement

    Install class-A analysers and log continuously at the agreed points.

  3. Analysis

    Correlate events, compare with the standards and identify root causes.

  4. Remediation

    Design and implement corrective measures, then verify with a re-measurement.

Deliverables

  • Measurement plan
  • 7-day logging data
  • Harmonic spectrum report
  • Event & waveform log
  • Compliance assessment
  • Mitigation recommendations
  • Cost–benefit summary
  • Executive presentation

Frequently asked questions

No. Analysers are connected with clamp-on CTs and voltage leads during a short, safe window; logging then runs without any interruption.

Typically one to two weeks: around 7 days of logging plus analysis and reporting.

We report against IEEE 519 for harmonics and IEC 61000-4-30 / EN 50160 for measurement methods and voltage characteristics.

Yes. We design, supply and install harmonic filters, PFI panels and protection upgrades, then verify the improvement.

Have a project in mind?

Tell us about your site, loads and goals. An engineer will reply within one working day with next steps.